62 Exam-based calculations
c Save the calculation. (See “To save a
calculation” on page 47.)
Gynecology (Gyn) calculations
Gynecology (Gyn) calculations include Uterus,
Ovary, Follicle, and Volume. For instructions to
calculate volume, see “Volume calculations” on
page 50.
To measure uterus or ovary
1 On a frozen 2D image, press the CALCS key.
2 From the calculations menu, select Gyn.
3 Do the following for each measurement you
want to take:
a Select the measurement name from the
calculations menu.
b Position the calipers. (See “Working with
calipers” on page 43.)
c Save the calculation. (See “To save a
calculation” on page 47.)
To measure follicles
On each side, you can save up to three distance
measurements on a follicle, for up to 10 follicles.
If you measure a follicle twice, the average appears
in the report. If you measure a follicle three times,
the average and a volume calculation appear in the
report.
1 On a frozen 2D image, press the
CALCS key.
2 From the calculations menu, select Follicle.
3 Do the following for each measurement you
want to take:
a From the calculations menu, select the
follicle number under Right Fol or Left Fol.
b Position the calipers. (See “Working with
calipers” on page 43.)
c Save the calculation. (See “To save a
calculation” on page 47.)
IMT calculations
WARNING:
To avoid incorrect calculations,
verify that the patient information,
date, and time settings are
accurate.
WARNING:
To avoid misdiagnosis or harming
the patient outcome, start a new
patient information form before
starting a new patient exam and
performing calculations. Starting a
new patient information form
clears the previous patient’s data.
The previous patient’s data will be
combined with the current patient
if the form is not first cleared. See
“To create a new patient
information form” on page 36.
Transducer Exam Type
C60x Gyn
ICTx Gyn
WARNING:
To ensure high quality images, all
patient images must be obtained
by qualified and trained individuals.
WARNING:
To avoid patient injury, IMT results
should not be used as a sole
diagnostic tool. All IMT results
should be interpreted in
conjunction with other clinical
information or risk factors.
WARNING:
To avoid measurement errors, all
measurements must be of the
common carotid artery (CCA).
This tool is not intended for
measuring the bulb or the internal
carotid artery (ICA).